;RSen_C_length##LENGTH##MILLIMETERS;REN_I Installation##OTHER##;RSen_M_flow_rate_Q_at_2Pa##HVAC_AIR_FLOW##CUBIC_METERS_PER_HOUR;RSen_M_flow_rate_Q_at_10Pa##HVAC_AIR_FLOW##CUBIC_METERS_PER_HOUR;RSen_C_model##OTHER##;RSen_C_description##OTHER##;RSen_C_height##LENGTH##MILLIMETERS;ZZZ_Binnen rooster_diepte_Length##LENGTH##MILLIMETERS;REN_I Sound reduction Dn,e,w (C,Ctr)_in open position##OTHER##;REN_I Airflow at 50 Pa (in closed position)##OTHER##;REN_I U-value##HVAC_COEFFICIENT_OF_HEAT_TRANSFER##WATTS_PER_SQUARE_METER_KELVIN;ZZZ_Binnen_geometrie_FamilyType_Air Terminals##OTHER##;RSen_C_code_article##OTHER##;RSen_M_flow_rate_Q_at_1Pa##HVAC_AIR_FLOW##CUBIC_METERS_PER_HOUR;RSen_M_flow_rate_Q_at_20Pa##HVAC_AIR_FLOW##CUBIC_METERS_PER_HOUR;REN_I Equivalent area (mm2/m)##OTHER##;REN_I Free area (mm2/m)##OTHER##;REN_I Finishing##OTHER##
window ventilation_renson_Sonoslot_lxhxd 275x35x78_275;275;Installation in a window frame;5,04;11,52;Sonoslot;renson_window ventilation_Sonoslot 275;35;15;38 (0,0) dB;<15%;1,4;GEO_787AK-788P : Standaard;Sonoslot 275;3,6;11,88;1273;1265;anodised / Renson standard WHITE, 9005, 1247
window ventilation_renson_Sonoslot_lxhxd 375x35x78_375;375;Installation in a window frame;6,12;14,4;Sonoslot;renson_window ventilation_Sonoslot 375;35;15;37 (0,0) dB;<15%;1,4;GEO_787AK-788P : Standaard;Sonoslot 375;4,68;15,12;1607;1885;anodised / Renson standard WHITE, 9005, 1247
window ventilation_renson_Sonoslot_lxhxd 475x35x78_475;475;Installation in a window frame;8,28;19,08;Sonoslot;renson_window ventilation_Sonoslot 475;35;15;36 (0,0) dB;<15%;1,4;GEO_787AK-788P : Standaard;Sonoslot 475;6,12;20,16;2121;2513;anodised / Renson standard WHITE, 9005, 1247
window ventilation_renson_Sonoslot_lxhxd 700x35x78_700;700;Installation in a window frame;12,24;28,8;Sonoslot;renson_window ventilation_Sonoslot 700;35;15;34 (0,0) dB;<15%;1,4;GEO_787AK-788P : Standaard;Sonoslot 700;9;30,24;3181;3769;anodised / Renson standard WHITE, 9005, 1247
window ventilation_renson_Sonoslot Max_lxhxd 700x45x78_with acoustic foam;700;Installation in a window frame;6,84;18,36;Sonoslot Max;renson_window ventilation_Sonoslot Max;45;50;40 (-1,-2) dB;n.b.;0;GEO_470 : Standaard;Sonoslot Max with acoustic foam;4,32;27,36;1555;1871;Renson standard WHITE / RAL 1247
window ventilation_renson_Sonoslot Max_lxhxd 700x45x78_without acoustic foam;700;Installation in a window frame;9,72;24,48;Sonoslot Max;renson_window ventilation_Sonoslot Max;45;50;38 (-1,-2) dB;n.b.;0;GEO_470 : Standaard;Sonoslot Max without acoustic foam;6,48;24,84;2298;1871;Renson standard WHITE / RAL 1247